Fire Rated Switch Box Insert
TENMAT Fire Rated Switch Box Inserts are a cost effective and simple solution for protecting electrical switch and socket boxes when fitted in fire rated walls.
The fire resistant material fully lines the socket to provide a fire seal that limits the spread of fire within and through the partition.
The Switch Box Inserts are pre-formed and can be installed in seconds without assembly or adhesives. The profiled design ensures that the insert can be simply push fitted into the electrical metal or plastic back boxes.
The flanged design also ensures that the Socket Box Insert remains in position during a fire even when fitted within plastic drylining boxes.
Offering significant labour and cost savings over plasterboard lining or putty pad solutions, the Socket Box Inserts are available to suit both single and double sockets.

For more information about airtightness, please click here.
Applications
  • Electrical Socket Penetrations
  • Fire Resistant Walls / Partitions
Properties
  • 2 Hour Fire Rated
  • Acoustic Properties
  • Fits in seconds
  • No adhesives, no mess
  • Fits inside back boxes
  • Improved airtightness and energy saving
Fire Testing Approvals

Chiltern
2 hour fire tested to BS476:part 20/22:1987 for both integrity and insulation.
Suitable for insulated and uninsulated plasterboard partitions.
Test no Chilt/RF08071 AR1
2 hour fire tested to the principles of BSEN 1363-1:1999 for both integrity and insulation.
Test no: Chilt/IF08039

Acoustic Testing Approvals
Tested in accordance with BS EN ISO 140-3:1995 and BS EN ISO 717-1:1997 under UKAS conditions in a timber stud wall construction. Test No.: 247373 / Building Research Establishment (BRE)
Certificate No.: 213942 / BRE
Regulations
Meets the requirements of UK Building Regulations Approved Document B